- The grease filter symbol lights after the set operating hours: 20, 30, 40 or 50, with 30 as the default. 1
- Delayed shutdown runs the blower on for 5 or 15 minutes after cooking. 1
- Grease filters can go in the dishwasher at up to 150°F (65°C); oversaturated filters are a fire hazard. 1
- Reset by touching the grease filter control for about 3 seconds after cleaning. 1
What do the lights on a Miele ventilation hood mean?#
Four things share the panel: the grease filter symbol, the charcoal filter symbol, the 5 and 15 lights, and the 1 to B power level lights. The symbols remind you to clean or change filters; 5 and 15 show the run-on time you picked. 1
This guide follows the Operating and Installation Instructions for the Miele Ventilation Hood, M.-Nr. 13 063 350 (US edition). The panel has sensor controls for the blower on and off, lighting and dimming, blower power levels 1 to 3 and B (booster), delayed shutdown, and a grease filter and a charcoal filter saturation control. 1
| On the panel | Meaning | Your move |
|---|---|---|
| Grease filter symbol lit | Filter saturation indicator: grease filters due | Clean them, then reset 1 |
| Charcoal filter symbol lit | Charcoal filter due (recirculation mode) | Change the filter, reset 1 |
| 5 or 15 lit | Delayed shutdown time chosen | Nothing; the blower stops by itself 1 |
| 1 and B flashing | Power management is off | Turn it on again if you want it 1 |
| 2 and 3 flashing | The WiFi connection to the cooktop could not finish, or it was canceled | Disconnect both and connect again 1 |
The same displays have rows in our code library: grease filter symbol lit, charcoal filter symbol lit, 5 or 15 lit and 1 and B flashing.
Why is the grease filter symbol lit?#
The hood registers how long it has run. When the set operating time is up, it lights the grease filter symbol to tell you the filters need cleaning. The factory default is 30 hours. 1
You can change the interval to suit how you cook. The manual lists 20 hours for regular frying, 30 hours as the default, and 40 or 50 hours if you use little fat. It also says a shorter interval is advisable if you only cook occasionally, because grease that sits solidifies and gets harder to clean. 1
Before the time is up you can check progress: with the blower on, press and hold the grease filter control, and one or more of the power level lights flash. One light means 25 percent, two 50, three 75 and all four 100. The elapsed time stays stored when the hood is switched off or there is a power interruption. 1
To change the interval, switch the blower and lighting off, touch the delayed shutdown control and the grease filter control at the same time, pick 1 to B (20, 30, 40, 50 hours) and confirm with the grease filter control. If you do not confirm within 4 minutes, the hood goes back to the old setting. 1
How do I clean the grease filters and reset the symbol?#
Disconnect the hood from power first. Release the locking clip, open the filter to about 45 degrees, unhook it and lift it out. Wash it in the sink or the dishwasher, let it dry, refit it and reset the symbol. 1
- 1
- 2
- 3
- 4
If you clean before the full time has elapsed, touch the grease filter control for about 6 seconds instead, until only the 1 flashes. 1 The manual says grease filters should be cleaned every 3 to 4 weeks. 1
Do not use lime removers, abrasive powders or liquids, aggressive all-purpose cleaners and degreaser sprays, or oven sprays on the filters. In the dishwasher, the inside surfaces may discolor with some cleaners; the manual says that does not affect how they work. 1
What do the 5 and 15 lights mean?#
They show delayed shutdown, a run-on timer. After cooking, touch the delayed shutdown control once and the blower stops after 5 minutes with 5 lit; touch it twice for 15 minutes with 15 lit; a third touch cancels it. 1
The manual recommends running the blower for a few minutes after cooking, because it neutralizes lingering vapors and odors and reduces the risk of residues building up in the hood. 1 So seeing 5 or 15 lit is the hood doing what you asked. It is not a warning, and it needs no reset.
On a hood paired with a Miele induction cooktop through Con@ctivity, the hood runs automatically and winds the blower down by itself after you turn the burners off, one level at a time, until it stops. In that mode the blower and then the lighting switch off on their own after the cooktop does. 1
What does a flashing 1 and B mean?#
Power management is off. When it is on, which is the default, 1 and B are steady lit when you open that setting. Power management lowers blower levels and switches off the lighting automatically to save energy. 1
With it on, booster drops to level 3 after 5 minutes, levels 3, 2 and 1 step down after 2 hours and then every 30 minutes until the blower stops, and the lighting goes off after 12 hours. With it off, the hood still shuts itself off after 12 hours if left on. 1 To change it, hold the delayed shutdown control for about 10 seconds until 1 lights, then press the lighting control, the 1 control and the lighting control again; touch 1 to switch it off or B to switch it on, and confirm with the delayed shutdown control. 1
What about the charcoal filter symbol?#
It only matters in recirculation mode. The hood is set at the factory for recirculation and must be reset for extraction mode, which deactivates the charcoal filter indicator. The default interval for the charcoal filter is 180 hours. 1
If your hood vents outside, the charcoal filter symbol should not be in use at all. The manual's reset sequence for extraction mode is: blower and lighting off, touch delayed shutdown and the charcoal filter control together, touch B, and confirm with the charcoal filter control. All lights go out and extraction mode is set. If you do not confirm within 4 minutes, the hood goes back to the earlier setting. 1 Recirculation needs a recirculation kit and an OdorFree charcoal filter, listed as optional accessories. 1 What a technician checks is on our hood service page.
Where a technician comes in#
Book when the symbol returns after cleaning and a reset, when the blower will not start, when a filter is bent or refuses to lock, or when the controls do not respond after switching the hood off and on. 1
Book a technician with us. A price is quoted and approved by you before work starts, with the final figure fixed after inspection in your kitchen. Hoods that are still under warranty are repaired by the maker; our repairs carry a workmanship warranty. Tell us the model, which lights were on and whether the hood vents outside or recirculates.